Inventory of Used MRI, Used CT, Used Ultrasound Equipment, and More!

Nationwide has an extensive inventory of diagnostic imaging equipment spanning all manufacturers including GE, Siemens and other manufacturers and modalities. Inventory includes used MRI, used CT, PET, cardiology, angiography, mammography, and used ultrasound equipment. Additional information, including specifications and availability, is included below. Please contact us to get more information or to locate equipment not shown in the inventory listings below.


Product: 2009 PHILIPS ALLURA XPER FD20 – NISR9425

Category:

Manufacturer:

Interested?
Give us a call at 732-262-3115 and speak to one of our representatives. You may also contact us online for more information.

Find out more.
Interested in learning more about this equipment? Submit your information below and a Nationwide representative will contact you with more information.

  • Location State Required
  • This field is for validation purposes and should be left unchanged.
  • Location: NJ WH
  • Availability: NOW
  • NIS: R9425

2009 PHILIPS ALLURA XPER FD20 NISR9425

SN 1839

ALLURA XPER FD-20 GANTRY/ TABLE

CEILING MOUNTED

SINGLE PLANE

SW 7.2.9

TYPE: SINGLE PLANE

PA GANTRY CONFIGURATION: C (CLEA)

DEPTH: 95 CM (37.4 IN.)

RAO PROJECTION: 185 HEAD

LAO PROJECTION: 120 HEAD

ROTATION RATE, DEG/SEC: VARIABLE UP TO 25

CRANIAL-TO-CAUDAL ANGULATION, DEG 90/90

SID RANGE: 89.5-119.5 CM (35-47 IN.)

MOTORIZED GANTRY/ TABLE

COUNTERBALANCED DIRECT DRIVE

MOUNT CONFIGURATIONS: CEILING-SUSPENDED OR FLOOR-MOUNTED

 

  • POWER CONSUMPTION

GENERAL SYSTEM : 480 VAC; 60 HZ; 3-PHASE

X-RAY GENERATOR: SUPPLIED BY SYSTEM

 

  • SITING REQUIREMENTS

ROOM SIZE NEEDED 7.6M X 5.3M (24.9 FT X 17.4 FT)

MINIMUM ROOM HEIGHT NEEDED: 2.9 M (9.5 FT.)

 

  • GENERATOR: HIGH FREQUENCY

POWER RATING (KW): @ 100 KVP 100

RADIOGRAPHIC (MA): 1-1,250

RADIOGRAPHIC (KV): 40-125

RADIOGRAPHIC TIMER: 2 MS-4 SEC

FLUOROSCOPIC (MA): 60 MA NOMINAL FOR PULSED FLUORO

FLUOROSCOPIC (KV): 40-125

PULSED FLUOROSCOPY: GRID SWITCHED

CINE CAMERA RANGE: 15, 30, AND 60 FPS OPTIONAL

 

  • 2017 ALLURA XPER FD20 X-RAY TUBE

 

SW OPTIONS

  • BEAM LIMITATION CONDITIONING
  • DIGITAL FILM MANAGEMENT
  • DIGITAL VIEWING
  • EXAM ADMIN FUNCTIONS
  • EXAM PRE SET
  • IMAGE GEN FUNCTIONS
  • INTRA IMAGE POST PROCESSING
  • PATIENT BEAM POSITIONING
  • 3D SOFT TISSUE PACKAGE
  • AQQUISITION MASK AVG
  • ADVANCED FS MAIN
  • AUTO CALIBRATE
  • SUBTRACTION
  • CARDIO FRAME RATE
  • CORONARY ANALYSIS
  • XRAYCON 1.0
  • DOUBLE STORAGE CAPACITY
  • DOUBLE SUBTRACTION
  • DYNAMIC ROTATIONAL ANGIO
  • EP TRIGGERING
  • EXT VIDEO
  • FAST ARCHIVING
  • INJECTOR COUPLING
  • ISO CENTER TABLE TILT
  • LEFT VENTRICAL ANALYSIS
  • LOOK OVER SHOULDER
  • PEDIATRIC FRAME RATE
  • ANGIO XRACON
  • XRAYCON PRINT
  • PRO ACTIVE LIVE
  • PROCEDURE LOGGING
  • QA BASICS
  • RIS CONNECTION
  • REAL TIME LINK
  • SUBTRACTION RUN
  • SMART MASK
  • CORRECTIVE MAINT
  • PLANNED MAINT
  • TEST SHOT LOCK IN
  • USB EXPORT
  • VASCULAR ANALYSIS
  • VIEW TRACE
  • XRES CARDIO EXPOSURE
  • XRES FLOURO
  • XTRA VISION

 

  • MAXIMUM NUMBER OF X-RAY TUBES: 1-HEAT STORAGE CAPACITY: 5400000 HU

HEAT DISSIPATION RATE: 910000 HU/MINFOCAL SPOT SIZE: 0.4/0.7 MM (MRC) GRID PULSED: YES

TARGET ANGLE: 11 DEGREES

COOLING METHOD: RECIRCULATING OIL

X-RAY DENSITY:

 

ALLURA XPER FD20 DETECTOR

 

GENERATOR: ASI DETECTOR WITH CSI SCINTILLATOR

DIMENSIONS: 40CM X 30CM (15.7 IN. X 11.8 IN.)

PIXEL SIZE: 154MM X 154MM

BIT DEPTH: 14

MAX FRAME RATE: 60 FPS

 

  • IMAGE STORAGE

 

1024 X 1024, IMAGES: 50000

ADDITIONAL STORAGE: UP TO 100,000 IMAGES

DIGITAL IMAGING SYSTEM: INTEGRATED

 

  • PATIENT TABLE

 

MAXIMUM PATIENT LOAD: 250 KG (550 LBS) WITH ADDITIONAL 50 KG (110 LBS) FOR CPR

MOVEMENT: 4-WAY FLOATING, XPER TABLE

DIMENSIONS (L X W): 319 CM X 50 CM (125.5 IN. X 20 IN.)

VERTICAL: 79-107 CM (31-42 IN.)

LATERAL: +/-18 CM (7.1 IN.)

LONGITUDINAL: 125 CM (49.2 IN.)

 

OTHER PHILIPS ALLURA XPER FD20 SPECIFICATIONS

 

NUMBER OF MONITORS: 2 CONTROL ROOM, 2 EXAM ROOM

MONITOR SIZES: 18-INCHES LCD

DICOM 3.0 COMPLIANT: YES

SPECIFIED USE: CARDIOVASCULAR, VASCULAR, SURGERY

OTHER SPECIFICATIONS: 2K IMAGING CHAIN, BODYGUARD PATIENT COLLISION AVOIDANCE.

FDA CLEARANCE: YES

CE MARK: YES

MARKETING REGION: WORLDWIDE

 

  • WORKSTATION WITH 8.1 SW

AVAILABLE NOW

LOCATED NJ WH