Stock Image
2019 OEC ELITE MTS MXR109824
- Vas 30
- Super C
- Non Touch
Digital Image Orientation
- Digitally adjusts image display for live and last image hold
- Automatic image update preserves image orientation settings applied during live and last image hold for subsequent images
- Image rotation
- Live and last image hold rotated in real-time
- On-screen display of rotation degrees
- Image reversal (left-to-right)
- Image invert (top-to-bottom)
- On-screen orientation indicator
(real-time feedback without fluoroscopy)
- Fully digital with precise 1 degree rotation increments or auto-repeat for quick rotation (CFD models)
Image Processing
- 5 k x 1.5 k x 16 bit: CFD
Generator
- 60 kHz high frequency
- 15 kW power
- Up to 120 kVp
- Continuous high level fluoroscopy (HLF) up to 20 mA
- Pulsed HLF up to 40 mA
- Digital spot up to 75 mA
- Full power from a standard wall outlet
Patented battery buffered design
31 cm CMOS Flat Panel Detector (CFD)
- Tri-mode 31 cm/21cm/15 cm
- Minimum central resolution (at display):
– 31 cm: 1.8 Ip/mm
– 21cm: 2.2 Ip/mm
– 15 cm: 2.4 Ip/mm
- Matrix: 1548 x 1524 total pixels
- DQE(0): 72%
- Pixel Pitch: 0 µm
- Removable grid with on-screen detection status
X-ray Tube
- Rotating anode X-ray tube
- 3 mm and 0.6 mm nominal focal spots
- Anode heat capacity: 300,000 HU
- Anode cooling rate: 85,000 HU/min
- Housing heat capacity: 1,600,000 HU/min
- Housing cooling rate:
- 31 cm CFD – 31,000 HU/min
PreView Collimator
- On-screen collimator position indication
- PreView iris collimator
- PreView Tungsten rotatable double leaf collimator
- Adjust collimators without X-ray exposure
Fluoroscopy Mode
- kVp range: 40 – 120
- mA range: 2 – 10 normal mode
0.2 – 20 HLF
- Auto and manual fluoroscopy modes
Pulsed Fluoroscopy Mode
- kVp range: 40 – 120
- mA range: 2 – 10 normal mode
0.2 – 40 HLF
- Pulse rate: 8 pps
- Pulse width: 25 ms
- Auto and manual pulsed fluoroscopy modes
- Reduces X-ray dose to patient and operator
Digital Spot Mode
- kVp range: 40 – 120
- mA range: Up to 75
- Automatic exposure termination and automatic image save
AutoTrak
Automatic Brightness Stabilization (ABS}
- Automatically seeks the subject anatomy anywhere within the imaging field
- Selects the optimum imaging technique by varying mA, kVp, and gain
- Automatically adjusts to anatomical size
and location
- Provides uniform image quality throughout the entire image
Image I.Q.
- Smart Window
- Dynamically senses the collimator position and automatically adjusts image brightness and contrast
- Smart Metal
- Adjusts brightness and contrast automatically and allows user to adjust sensitivity levels for optimum image quality even when metal is introduced into the field
- Tungsten Collimator
- Denser collimator limits X-ray exposure area
- Reduces scatter radiation
- Improves image detail
Available Feb
Locate in NJ