Stock Image

 

2019 OEC ELITE MTS MXR109824

 

  • Vas 30
  • Super C
  • Non Touch

 

 

Digital Image Orientation

  • Digitally adjusts image display for live and last image hold
  • Automatic image update preserves image orientation settings applied during live and last image hold for subsequent images
    • Image rotation
    • Live and last image hold rotated in real-time
    • On-screen display of rotation degrees
    • Image reversal (left-to-right)
    • Image invert (top-to-bottom)
  • On-screen orientation indicator

(real-time feedback without fluoroscopy)

  • Fully digital with precise 1 degree rotation increments or auto-repeat for quick rotation (CFD models)

 

Image Processing

  • 5 k x 1.5 k x 16 bit: CFD

 

Generator

  • 60 kHz high frequency
  • 15 kW power
  • Up to 120 kVp
  • Continuous high level fluoroscopy (HLF) up to 20 mA
  • Pulsed HLF up to 40 mA
  • Digital spot up to 75 mA
  • Full power from a standard wall outlet

Patented battery buffered design

 

 

31 cm CMOS Flat Panel Detector (CFD)

  • Tri-mode 31 cm/21cm/15 cm
  • Minimum central resolution (at display):

– 31 cm: 1.8 Ip/mm

– 21cm: 2.2 Ip/mm

– 15 cm: 2.4 Ip/mm

  • Matrix: 1548 x 1524 total pixels
  • DQE(0): 72%
  • Pixel Pitch: 0 µm
  • Removable grid with on-screen detection status

 

 

 

 

 

 

X-ray Tube

  • Rotating anode X-ray tube
  • 3 mm and 0.6 mm nominal focal spots
  • Anode heat capacity: 300,000 HU
  • Anode cooling rate: 85,000 HU/min
  • Housing heat capacity: 1,600,000 HU/min
  • Housing cooling rate:
    • 31 cm CFD – 31,000 HU/min

 

 

PreView Collimator

  • On-screen collimator position indication
  • PreView iris collimator
  • PreView Tungsten rotatable double leaf collimator
  • Adjust collimators without X-ray exposure

 

Fluoroscopy Mode

  • kVp range: 40 – 120
  • mA range: 2 – 10 normal mode

0.2 – 20 HLF

  • Auto and manual fluoroscopy modes

 

Pulsed Fluoroscopy Mode

  • kVp range: 40 – 120
  • mA range: 2 – 10 normal mode

0.2 – 40 HLF

  • Pulse rate: 8 pps
  • Pulse width: 25 ms
  • Auto and manual pulsed fluoroscopy modes
  • Reduces X-ray dose to patient and operator

 

Digital Spot Mode

  • kVp range: 40 – 120
  • mA range: Up to 75
  • Automatic exposure termination and automatic image save

 

 

AutoTrak

Automatic Brightness Stabilization (ABS}

  • Automatically seeks the subject anatomy anywhere within the imaging field
  • Selects the optimum imaging technique by varying mA, kVp, and gain
  • Automatically adjusts to anatomical size

and location

  • Provides uniform image quality throughout the entire image

 

 

 

Image I.Q.

  • Smart Window
    • Dynamically senses the collimator position and automatically adjusts image brightness and contrast
  • Smart Metal
    • Adjusts brightness and contrast automatically and allows user to adjust sensitivity levels for optimum image quality even when metal is introduced into the field
  • Tungsten Collimator
    • Denser collimator limits X-ray exposure area
    • Reduces scatter radiation
    • Improves image detail

 

 

Available Feb

 

Locate in NJ

Categories:

Tags:

Contact Us To
Find Out More

Nationwide Imaging Logo